| 8
- Channel |
12 - Channel |
Multichannel
Micropipettes
• Non Autoclavable
• Fully Autoclavable
Features
High accuracy and precision for 96-well
microtitre
plates.
Extended volume range upto 300µl.
Comfortable, light weight and soft plunger
movement.
Seperate tip ejector allows easy tip ejection.
Recommended
for ELISA, Molecule screening, Kinetic studies, DNA
amplifications etc.
Non Autoclavable
Ordering
Information and Specifications
• 8
- Channel
| Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
| MC-8/10 |
0.5-10
|
0.1
µl |
1µl
5µl
10µl
|
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
| MC-8/20 |
2-20
|
0.1
µl |
2µl
10µl
20µl |
4%
1.50%
1.50% |
4%
1.50%
1.00% |
| MC-8/50 |
5-50
|
1
µl |
5µl
25µl
50µl
|
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
| MC-8/100 |
10-100
|
1
µl |
10µl
50µl
100µl
|
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
| MC-8/300 |
40-300 |
1
µl |
40µl
150µl
300µl
|
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |
• 12
- Channel
| Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
| MC-12/10 |
0.5-10
|
0.1
µl |
1µl
5µl
10µl
|
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
| MC-12/20 |
2-20
|
0.1
µl |
2
µl
10
µl
20
µl
|
4%
1.50%
1.50% |
4%
1.50%
1.00% |
| MC-12/50 |
5-50
|
1
µl |
5µl
25µl
50µl
|
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
| MC-12/100 |
10-100
|
1
µl |
10
µl
50
µl
100
µl
|
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
| MC-12/300 |
40-300 |
1
µl |
40µl
150µl
300µl
|
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |
 |
 |
| 8
- Channel |
12 - Channel |
Fully Autoclavable
Ordering
Information and Specifications
• 8
- Channel
Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
MCA-8/10 |
0.5-10 |
0.1 µl |
1µl
5µl
10µl |
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
MCA-8/20 |
2-20 |
0.1 µl |
2µl
10µl
20µl |
4%
1.50%
1.50% |
4%
1.50%
1.00% |
MCA-8/50 |
5-50 |
1 µl |
5µl
25µl
50µl |
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
MCA-8/100 |
10-100 |
1 µl |
10µl
50µl
100µl |
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
MCA-8/300 |
40-300 |
1 µl |
40µl
150µl
300µl |
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |
• 12
- Channel
Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
MCA-12/10 |
0.5-10 |
0.1 µl |
1µl
5µl
10µl |
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
MCA-12/20 |
2-20 |
0.1 µl |
2 µl
10 µl
20 µl |
4%
1.50%
1.50% |
4%
1.50%
1.00% |
MCA-12/50 |
5-50 |
1 µl |
5µl
25µl
50µl |
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
MCA-12/100 |
10-100 |
1 µl |
10 µl
50 µl
100 µl |
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
MCA-12/300 |
40-300 |
1 µl |
40µl
150µl
300µl |
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |