| Model |
Description |
Vol.(
µl ) |
Inaccuracy(%) |
C.V.(%) |
| VVCS
- 10 |
0.5
- 10 µl |
0.5
5.0
10.0 |
±
5.0
± 1.5
± 1.0 |
£2.8
£0.8
£0.4 |
| VVCS
- 20 |
2
-20 µl |
2.0
10.0
20.0 |
±
5.0
± 1.0
± 1.0 |
£1.5
£0.6
£0.3 |
| VVCS
- 50 |
5
- 50 µl |
5.0
25.0
50.0 |
±
2.5
± 0.7
± 0.7 |
£1.5
£0.3
£0.3 |
| VVCS
- 100 |
20
- 100 µl |
20.0
50.0
100.0 |
±
2.0
± 0.7
± 0.8 |
£0.7
£0.3
£0.2 |
| VVCS
- 200 |
40
- 200 µl |
40.0
100.0
200.0 |
±
1.5
± 0.6
± 0.6 |
£0.3
£0.3
£0.2 |
| VVCS
-1000 |
200
- 1000 µl |
200.0
500.0
1000.0 |
±
1.2
± 0.6
± 0.5 |
£0.3
£0.2
£0.2 |
| VVCS
- 5000 |
1-5 ml |
1000.0
2500.0
5000.0 |
±
0.8
± 0.6
± 0.6 |
£0.2
£0.2
£0.2 |
| VVCS
- 10000 |
2
- 10 ml |
2000.0
5000.0
10000.0 |
±
1.2
± 0.6
± 0.6 |
£0.2
£0.2
£0.2 |
| Extended
volume ranges, 10-100 µl,
20-200 µl,
100-1000 µl
are also available on request. |
| Fixed
Volume Micropipettes |
| FV
|
Capacity
Required (Example : To order for 50
ml Fixed Volume Pipettes write FV-50
And indicate quantity) |
1.0
2.0 5.0
10.0
15.0
20.0-40.0 50.0-90.0 100.0-10000.0 |
±
2.5
± 2.0
± 1.5
± 1.0
± 0.5
± 0.3
± 0.3 |
£
1.8
£
1.2
£
0.8
£
0.5
£
0.3
£
0.3
£
0.2 |
| Fully
Autoclavable Adjustable Volume |
| Model |
Vol.
Range |
Increment |
Vol. |
|
|
| FAA
- 2 |
0.2
- 2.0
µl |
0.01 |
0.2
1.0
2.0
|
12
.0
2.5
1.5 |
0.024
0.025
0.03 |
6.0
1.5
0.7 |
0.012
0.015
0.014 |
| FAA
- 10 |
0.5
- 10
µl |
0.1 |
0.5
5.0
10.0
|
5.0
1.5
1.0 |
0.025
0.075
0.1 |
2.8
0.8
0.4 |
0.14
0.04
0.04 |
| FAA
- 20 |
2
- 20
µl |
0.1 |
2.0
10.0
20.0 |
5.0
1.0
1.0 |
0.1
0.1
0.2 |
1.5
0.6
0.3 |
0.03
0.06
0.06 |
| FAA
- 50 |
5
- 50 µl |
1.0 |
5.0
25.0
50.0 |
2.5
0.7
0.7 |
0.125
0.175
0.35 |
1.5
0.3
0.3
|
0.075
0.075
0.15 |
| FAA
- 100 |
10
-100
µl |
1.0 |
10.0
50.0
100.0
|
2.5
0.8
0.8
|
0.25
0.4
0.8 |
0.7
0.15
0.15 |
0.07
0.15
0.15 |
| FAA
- 200 |
20
-200
µl |
1.0 |
20.
100.0
200.0 |
2.5
1.0
0.6 |
0.5
1.0
1.2 |
0.7
0.3
0.2 |
0.14
0.3
0.2 |
| FAA
- 1000 |
100
-1000 µl |
10.0 |
100.0
500.
1000.0 |
1.6
0.6
0.5 |
1.6
3.0
5.0 |
0.3
0.2
0.2 |
0.3
1.0
2.0 |
| FAA
- 5000 |
0.5
- 5 ml |
100.0 |
500.0
2500.0
5000.0
|
1.5
0.6
0.6 |
7.5
15.0
30.0 |
0.3
0.2
0.2 |
1.5
5.0
10.0 |
| FAA
- 10000 |
1
-10 ml |
100.0 |
1000.0
5000.0
10000.0 |
1.5
0.6
0.6 |
15.0
30.0
60.0 |
0.3
0.2
0.2 |
3.0
15.0
30.0 |
Fully
Autoclavable Fixed Volume |
| Fully
Autoclavable Fixed |
Volume
µl |
Inaccuracy
(%) |
C.V(%) |
|
Model FAF
Capacity Requried
(To order for 50 Fully Autoclavable
Fixed Volume Pipettes, write
FAF - 50 and Indicate quantity)
|
1.0 |
±
2.5 |
£1.8 |
| 2.0 |
±
2.0 |
£1.2 |
| 5.0 |
±
1.5 |
£0.8 |
| 10.0 |
±
1.0 |
£0.5 |
| 15.0 |
±
1.0 |
£0.5 |
| 20.0-40.0 |
±
0.5 |
£0.3 |
| 50.0-90.0 |
±
0.3 |
£0.3 |
| 100.0-10000.0 |
±
0.3 |
£0.2 |
|
Multichannel
Micropipettes
Non Autoclavable ( 8
Channel )
| Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
| MC-8/10 |
0.5-10
|
0.1
µl |
1µl
5µl
10µl
|
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
| MC-8/20 |
2-20
|
0.1
µl |
2µl
10µl
20µl |
4%
1.50%
1.50% |
4.00%
1.50%
1.00% |
| MC-8/50 |
5-50
|
1
µl |
5µl
25µl
50µl
|
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
| MC-8/100 |
10-100
|
1
µl |
10µl
50µl
100µl
|
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
| MC-8/300 |
40-300 |
1
µl |
40µl
150µl
300µl
|
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |
Non Autoclavable ( 12
Channel )
| Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
| MC-12/10 |
0.5-10
|
0.1
µl |
1µl
5µl
10µl
|
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
| MC-12/20 |
2-20
|
0.1
µl |
2
µl
10
µl
20
µl
|
4.00%
1.50%
1.50% |
4.00%
1.50%
1.00% |
| MC-12/50 |
5-50
|
1
µl |
5µl
25µl
50µl
|
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
| MC-12/100 |
10-100
|
1
µl |
10
µl
50
µl
100
µl
|
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
| MC-12/300 |
40-300 |
1
µl |
40µl
150µl
300µl
|
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |
| Fully Autoclavable ( 8
Channel ) |
Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
MCA-8/10 |
0.5-10 |
0.1 µl |
1µl
5µl
10µl |
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
MCA-8/20 |
2-20 |
0.1 µl |
2µl
10µl
20µl |
4%
1.50%
1.50% |
4%
1.50%
1.00% |
MCA-8/50 |
5-50 |
1 µl |
5µl
25µl
50µl |
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
MCA-8/100 |
10-100 |
1 µl |
10µl
50µl
100µl |
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
MCA-8/300 |
40-300 |
1 µl |
40µl
150µl
300µl |
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |
|
| Fully Autoclavable ( 12
Channel ) |
Model |
Vol.
Range |
Increments |
Test
Vol. |
Inaccuracy |
Imprecision |
MCA-12/10 |
0.5-10 |
0.1 µl |
1µl
5µl
10µl |
4.00%
2.50%
1.50% |
4.00%
2.50%
1.50% |
MCA-12/20 |
2-20 |
0.1 µl |
2 µl
10 µl
20 µl |
4%
1.50%
1.50% |
4%
1.50%
1.00% |
MCA-12/50 |
5-50 |
1 µl |
5µl
25µl
50µl |
3.00%
1.50%
0.50% |
2.00%
1.00%
0.50% |
MCA-12/100 |
10-100 |
1 µl |
10 µl
50 µl
100 µl |
1.50%
1.00%
1.00% |
1.50%
0.50%
0.50% |
MCA-12/300 |
40-300 |
1 µl |
40µl
150µl
300µl |
1.50%
1.00%
0.70% |
0.80%
0.50%
0.25% |
|
| Electronic
Micropipettes |
| Model |
Vol.
Range |
Increments |
Tip
Style |
|
ME
- 10 |
0.2-10
µl |
0.05µl |
10µl |
| ME
- 120 |
5-120µl |
0.5µl |
200µl |
| ME
- 300 |
20-300µl |
1.0µl |
300µl |
| ME
- 1000 |
50-1000µl |
5.0µl |
1000µl |
| ME
- 5000 |
100-5000µl |
10.0µl |
5000µl |
| ME
- 10000 |
500-10000µl |
50.0µl |
10000µl |
| E-fill |
| Model
No. |
Description |
| MPF
- GY - 220V |
Grey
body/ yellow collet and
plungers |
| MPF
- GY - 110V |
Grey
body/ yellow collet and
plungers |
| MPF
- GR - 220V |
Grey
body/ red collet and plungers |
| MPF
- GR - 110V |
Grey
body/ red collet and plungers |
| MPF
- GV - 220V |
Grey
body/ Violet collet and
plungers |
| MPF
- GV - 110V |
Grey
body/ Violet collet and
plungers |
Li'lpet |
| Model |
Capacity |
Accuracy |
CV |
| MM-5 |
5
µl |
1.5% |
1.0% |
| MM-10 |
10
µl |
1.0% |
1.0% |
| MM-20 |
20
µl |
0.5% |
0.5% |
| MM-25 |
25
µl |
0.5% |
0.5% |
| MM-50 |
50
µl |
0.4% |
0.3% |
| MM-100 |
100
µl |
03% |
0.3% |
|
Model |
Capacity |
Accuracy |
CV |
MM-200 |
200 µl |
0.5% |
0.5% |
MM-250 |
250 µl |
0.5% |
0.5% |
MM-500 |
500 µl |
0.5% |
0.5% |
MM-1000 |
1000 µl |
0.5% |
0.5% |
|
|
| Tips
for Micropipettes |
| Model |
Description |
| MTSP
|
Capacity
upto 10 µl Pkt. of 100 Nos. |
| MT
- I |
Capacity
upto 200 µl Pkt. of 500 Nos. |
| MT
- II |
Capacity
upto 1000 µl Pkt. of 500 Nos. |
| MT
- V |
Capacity
upto 5000 µl Pkt. of 100 Nos. |
| MT
- IV |
Capacity
upto 10000 µl Pkt. of 100 Nos. |
Bottle Top Dispenser
Model No. |
Vol. Range |
Increment |
ISO 8655 Specifications |
Microlit Specification |
Classic Model |
Research Model |
Accuracy |
CV |
Accuracy |
CV |
| |
|
|
|
± % |
± ml |
± % |
± ml |
± % |
± ml |
± % |
± ml |
BTD-1 |
BTDR-1 |
0.25-2.5 ml |
0.05 ml |
0.6 |
0.015 |
0.2 |
0.005 |
0.6 |
0.015 |
0.2 |
0.005 |
BTD-2 |
BTDR-2 |
0.5-5 ml |
0.1 ml |
0.6 |
0.030 |
0.2 |
0.010 |
0.5 |
0.025 |
0.1 |
0.005 |
BTD-3 |
BTDR-3 |
1-10 ml |
0.2 ml |
0.6 |
0.060 |
0.2 |
0.020 |
0.5 |
0.050 |
0.1 |
0.010 |
BTD-4 |
BTDR-4 |
2.5-30 ml |
0.5 ml |
0.6 |
0.180 |
0.2 |
0.060 |
0.5 |
0.150 |
0.1 |
0.030 |
BTD-5 |
BTDR-5 |
5-60 ml |
1.0 ml |
0.6 |
0.360 |
0.2 |
0.120 |
0.5 |
0.300 |
0.1 |
0.060 |
|
| Micropipette-Stands |
Model |
Description |
MS - I |
Acrylic stand for 3 pipettes |
MS -II |
Acrylic stand for 6 pipettes |
MS -III |
Acrylic stand for 8-Channel pipettes |
MS -IV |
Acrylic stand for 12-Channel pipettes |
|
| |
|
| |